Almon Healthcare Private Limited
Registered Address: India (India)
5 Questions to Ask Almon Healthcare Private Limited Before Signing a Manufacturing Contract
Bring these exact questions to your discovery call with their QA Director or account rep before wiring a production deposit:
- Q1: On 2026-02-13, FDA cited 21 CFR 211.194(a)(5) (Finished Product Testing, Stability & Expiration Dating). Can your Quality Unit share the signed 15-day CAPA response and verification logs showing this gap is closed?
- Q2: On 2026-02-13, FDA cited 21 CFR 212.20(c) (Incoming Ingredient Identity Testing & COA Qualification). Can your Quality Unit share the signed 15-day CAPA response and verification logs showing this gap is closed?
- Q3: On 2026-02-13, FDA cited 21 CFR 212.70(c) (Master Manufacturing & Batch Production Records (MMR/BPR)). Can your Quality Unit share the signed 15-day CAPA response and verification logs showing this gap is closed?
- Q4: Do you perform 100% FTIR/HPLC identity testing on incoming active ingredients in-house (21 CFR 111.75(a)(1)), or do you rely on vendor COAs?
- Q5: Will you sign our Quality Agreement Rider requiring 24-hour notification if an FDA investigator issues a Form 482 or Form 483 at FEI 3030509366?
Cross-Database Regulatory & Inspection Timeline
Unified chronological history across FDA ORA Inspections, Form 483s, Warning Letters, Enforcement Recalls, and OASIS Import Refusals.
FDA Form 483 issued to Almon Healthcare Private Limited (FEI 3030509366) on 2026-02-13 following an inspection of its api manufacturer operations in India. The report documents 5 inspection observations centered on Finished Product Testing, Stability & Expiration Dating, Incoming Ingredient Identity Testing & COA Qualification.
- 21 CFR 211.194(a)(5) (Finished Product Testing, Stability & Expiration Dating): Releasing finished batches without verifying strength/potency/microbiological specs, or placing an expiration/best-by date on labels without supporting real-time or accelerated stability data.
- 21 CFR 212.20(c) (Incoming Ingredient Identity Testing & COA Qualification): Failure to perform at least one test to verify the identity of every incoming dietary ingredient or raw component before use, or relying on a supplier's Certificate of Analysis (COA) without first qualifying the supplier.
- 21 CFR 212.70(c) (Master Manufacturing & Batch Production Records (MMR/BPR)): Missing Master Manufacturing Records (MMRs) or incomplete Batch Production Records (BPRs) lacking exact component weights, lot numbers, yield reconciliation, or second-person verification.
- 21 CFR 314.80(c)(2)(ii)(B) (Electronic Record Data Integrity (21 CFR Part 11) & Retention): Uncontrolled spreadsheets, shared laboratory logins, missing audit trails, backdated entries, or failure to retain batch and distribution records for the statutory window. REPEAT OBSERVATION
- 21 CFR 211.28(a) (Personnel GMP Training, Gowning & Hygienic Practices): Operators performing manufacturing or QA tasks without documented GMP/SOP training, or observed gowning/hygiene deviations in production rooms.
Manufacturer Right-of-Reply & Free Match Correction
GUARDRAIL PROTECTEDTo ensure fairness and accuracy, facility owners may submit verified Form 483 closeout evidence, CAPA completion statements, or entity-resolution corrections free of charge. Sponsorship never alters an FDA Record Index score.
6-Subsystem cGMP Radar Breakdown
Sub-scores mapped across FDA's six core inspection subsystems.
Verified AAA/AA Co-Packers in This Sector
Compare or request quotes from top-rated contract manufacturers with clean FDA inspection histories:
Score Provenance Receipts
Every point in this facility's FDA Record Index (68/100) is backed by a linked government record (36-month half-life decay).
| Event | Date | Weight | Receipt |
|---|---|---|---|
| Inspection Outcome (VAI) | 2026-02-13 | -8.5 pts | INSP-483-3030509366-20260213 ↗ |
| Form 483 (5 observations, 1 repeat) | 2026-02-13 | -15.2 pts | 483-3030509366-20260213 ↗ |