FDA Form 483 issued to JFC International, Inc (FEI 3004273032) on 2026-02-20 following an inspection of its importer/warehouse/repacker operations in Texas. The report documents 3 inspection observations centered on Electronic Record Data Integrity (21 CFR Part 11) & Retention, Finished Product Testing, Stability & Expiration Dating.
Get Full Annotated 483 Dossier + CAPA Checklist
Instant PDF + CFR Matrix ($79 vs. Redica's $289)
Need Help Fixing These 3 Citations?
Get matched with a vetted 21 CFR remediation consultant
Observation-by-Observation 21 CFR Breakdown (3)
Observation #1 · 21 CFR 211.42(c)(10)(iii)
Electronic Record Data Integrity (21 CFR Part 11) & Retention
FIRST-TIME OBSERVATION
Air Supply
Inspector Observation Language: "Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, observed during inspection of JFC International, Inc on 2026-02-20."
Plain-English Meaning: Uncontrolled spreadsheets, shared laboratory logins, missing audit trails, backdated entries, or failure to retain batch and distribution records for the statutory window.
Standard CAPA Remediation Path: Enforce unique user credentials, immutable audit trails on analytical instruments, controlled form issuance numbers, and 2-year post-expiration record retention.
Observation #2 · 21 CFR 211.166(a)(1)
Finished Product Testing, Stability & Expiration Dating
FIRST-TIME OBSERVATION
Sample size - test intervals
Inspector Observation Language: "The written stability program for drug products does not include [sample size] [test intervals] based on statistical criteria for each attribute examined to assure valid estimates of stability. Specifically, observed during inspection of JFC International, Inc on 2026-02-20."
Plain-English Meaning: Releasing finished batches without verifying strength/potency/microbiological specs, or placing an expiration/best-by date on labels without supporting real-time or accelerated stability data.
Standard CAPA Remediation Path: Require finished-batch microbiological (USP <2021>/<2022>), heavy metal, and active-assay release testing plus ICH stability chamber protocols supporting every label shelf-life claim.
Observation #3 · 21 CFR 211.186(a)
Electronic Record Data Integrity (21 CFR Part 11) & Retention
REPEAT CITATION AT FACILITY
Written procedures followed
Inspector Observation Language: "Procedures for the preparation of master production and control records are not [described in a written procedure] [followed]. Specifically, observed during inspection of JFC International, Inc on 2026-02-20."
Plain-English Meaning: Uncontrolled spreadsheets, shared laboratory logins, missing audit trails, backdated entries, or failure to retain batch and distribution records for the statutory window.
Standard CAPA Remediation Path: Enforce unique user credentials, immutable audit trails on analytical instruments, controlled form issuance numbers, and 2-year post-expiration record retention.