CC0 PUBLIC RECORD GRAPH Every score & timeline item links directly to its underlying U.S. FDA record (openFDA, ORA FOIA Reading Room, DECRS & OASIS).
FG
GMPGraphv2.0
Global FDA Facility Graph & Co-Packer Intelligence
Form 483 Library → Juicer Connections, Inc. → 483-3004418300-20250908
Form FDA 483 · Issued 2025-09-08

Juicer Connections, Inc. — FDA Form 483 Analysis

FEI: 3004418300 · Sector: Pharmaceuticals & Sterile/OTC Drugs (Manufacturer) · Lead Investigator: David K. Chen

FDA Form 483 issued to Juicer Connections, Inc. (FEI 3004418300) on 2025-09-08 following an inspection of its manufacturer operations in California. The report documents 4 inspection observations centered on Incoming Ingredient Identity Testing & COA Qualification, Finished Product Testing, Stability & Expiration Dating.

Get Full Annotated 483 Dossier + CAPA Checklist
Instant PDF + CFR Matrix ($79 vs. Redica's $289)
Buy Dossier ($79)
Need Help Fixing These 4 Citations?
Get matched with a vetted 21 CFR remediation consultant
Request Consultant

Observation-by-Observation 21 CFR Breakdown (4)

Observation #1 · 21 CFR 211.160(b)(1) Incoming Ingredient Identity Testing & COA Qualification
FIRST-TIME OBSERVATION
Samples (various types) representative, identified properly
Inspector Observation Language: "Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of [components] [drug product containers] [closures] [labeling] are not [representative] [adequately identified]. Specifically, observed during inspection of Juicer Connections, Inc. on 2025-09-08."
Plain-English Meaning: Failure to perform at least one test to verify the identity of every incoming dietary ingredient or raw component before use, or relying on a supplier's Certificate of Analysis (COA) without first qualifying the supplier.
Standard CAPA Remediation Path: Establish SOP-QA-004 requiring FTIR/HPLC/organoleptic identity testing on 100% of incoming dietary ingredient lots and annual audit + 3-lot confirmatory testing before relying on any vendor COA.
Observation #2 · 21 CFR 211.160(b)(4) Finished Product Testing, Stability & Expiration Dating
FIRST-TIME OBSERVATION
Instruments, apparatus, et. al. not meeting specs
Inspector Observation Language: "The use of [instruments] [apparatus] [gauges] [recording devices] not meeting established specifications was observed. Specifically, observed during inspection of Juicer Connections, Inc. on 2025-09-08."
Plain-English Meaning: Releasing finished batches without verifying strength/potency/microbiological specs, or placing an expiration/best-by date on labels without supporting real-time or accelerated stability data.
Standard CAPA Remediation Path: Require finished-batch microbiological (USP <2021>/<2022>), heavy metal, and active-assay release testing plus ICH stability chamber protocols supporting every label shelf-life claim.
Observation #3 · 21 CFR 211.188(b)(11) Master Manufacturing & Batch Production Records (MMR/BPR)
REPEAT CITATION AT FACILITY
Identification of persons involved, each significant step
Inspector Observation Language: "Batch production and control records do not include the identification of the persons [performing] [directly supervising] [checking] each significant step in the operation, for each batch of drug product produced. Specifically, observed during inspection of Juicer Connections, Inc. on 2025-09-08."
Plain-English Meaning: Missing Master Manufacturing Records (MMRs) or incomplete Batch Production Records (BPRs) lacking exact component weights, lot numbers, yield reconciliation, or second-person verification.
Standard CAPA Remediation Path: Ensure every product SKU has an approved MMR matching the exact label claim and every batch record captures raw material lot traceability, in-process weight/pH checks, and QA release signatures.
Observation #4 · 21 CFR 211.198(a) Incoming Ingredient Identity Testing & COA Qualification
FIRST-TIME OBSERVATION
Complaints reviewed by Quality Control Unit
Inspector Observation Language: "Written procedures describing the handling of complaints do not include provisions for [review by the quality control unit of any complaint involving the possible failure of a drug product to meet any of its specifications] [a determination as to the need for an investigation of any unexplained discrepancy] [explaining the reasons for the failure of the batch or any of its components to meet specifications]. Specifically, observed during inspection of Juicer Connections, Inc. on 2025-09-08."
Plain-English Meaning: Failure to perform at least one test to verify the identity of every incoming dietary ingredient or raw component before use, or relying on a supplier's Certificate of Analysis (COA) without first qualifying the supplier.
Standard CAPA Remediation Path: Establish SOP-QA-004 requiring FTIR/HPLC/organoleptic identity testing on 100% of incoming dietary ingredient lots and annual audit + 3-lot confirmatory testing before relying on any vendor COA.