21 CFR 820.100(a) Devices
Rank #1 ยท 279 Annual FDA Citations
21 CFR 820.100(a): Lack of or inadequate procedures

Failure to thoroughly investigate unexplained batch discrepancies, Out-of-Specification lab results, or consumer complaints/adverse events and document root-cause Corrective and Preventive Actions (CAPA).

Official Inspector Observation Language: "Procedures for corrective and preventive action have not been [adequately] established. Specifically, ***..."
Theme: CAPA, Out-of-Specification (OOS) & Complaint Investigations
21 CFR 820.198(a) Devices
Rank #2 ยท 211 Annual FDA Citations
21 CFR 820.198(a): Lack of or inadequate complaint procedures

Failure to thoroughly investigate unexplained batch discrepancies, Out-of-Specification lab results, or consumer complaints/adverse events and document root-cause Corrective and Preventive Actions (CAPA).

Official Inspector Observation Language: "Procedures for receiving, reviewing, and evaluating complaints by a formally designated unit have not been [adequately] established. Specifically,***..."
Theme: CAPA, Out-of-Specification (OOS) & Complaint Investigations
21 CFR 820.50 Devices
Rank #3 ยท 115 Annual FDA Citations
21 CFR 820.50: Purchasing controls, Lack of or inadequate procedures

Failure to develop or maintain a Foreign Supplier Verification Program (FSVP) or approved vendor qualification file verifying that raw material suppliers meet U.S. FDA safety standards.

Official Inspector Observation Language: "Procedures to ensure that all purchased or otherwise received product and services conform to specified requirements have not been [adequately] established. Specifically, ***..."
Theme: Supplier Qualification & Foreign Supplier Verification (FSVP)
21 CFR 820.90(a) Devices
Rank #4 ยท 95 Annual FDA Citations
21 CFR 820.90(a): Nonconforming product, Lack of or inadequate procedures

Uncontrolled spreadsheets, shared laboratory logins, missing audit trails, backdated entries, or failure to retain batch and distribution records for the statutory window.

Official Inspector Observation Language: "Procedures have not been [adequately] established to control product that does not conform to specified requirements. Specifically, ***..."
Theme: Electronic Record Data Integrity (21 CFR Part 11) & Retention
21 CFR 820.75(a) Devices
Rank #5 ยท 93 Annual FDA Citations
21 CFR 820.75(a): Lack of or inadequate process validation

Scales, thermometers, pH meters, autoclaves, or purified water systems lacking current NIST-traceable calibration or process validation.

Official Inspector Observation Language: "A process whose results cannot be fully verified by subsequent inspection and test has not been [adequately] validated according to established procedures. Specifically, ***..."